Page 1 - Version 2.0.1

MCU 4200 Series Remote Management API This specification may be subject to change without notice Codian Confidential

Page 2 - Revision History

Codian MCU 4200 Series Remote Management API 2.4 conference.end Parameter Type Comments conferenceName string Name of the conference to be end

Page 3 - Introduction

Codian MCU 4200 Series Remote Management API 2.5 conference.participant.add Parameter Type Comments conferenceName string The name of the con

Page 4

Codian MCU 4200 Series Remote Management API All participants in a conference must have a “participantName” that is unique to the conference but

Page 5

Codian MCU 4200 Series Remote Management API 2.7 conference.participant.modify Parameter Type Comments conferenceName string autoAttendantUniqu

Page 6 - 2 Messages

Codian MCU 4200 Series Remote Management API 2.9 participant.disconnect Parameter Type Comments conferenceName string autoAttendantUniqueId str

Page 7

Codian MCU 4200 Series Remote Management API Response Type Comments participantName string participantProtocol string participantType string co

Page 8 - 2.2 conference.modify

Codian MCU 4200 Series Remote Management API videoRxLost int videoRxReceived int videoTxCodec string videoTxReportedLost int videoTxSent i

Page 9 - 2.3 conference.destroy

Codian MCU 4200 Series Remote Management API Response Type Comments conferenceName string conferenceType string one of: scheduled ad_hoc conf

Page 10 - 2.4 conference.end

Codian MCU 4200 Series Remote Management API following list: monday tuesday wednesday thursday friday saturday sunday eg. “monday,wednesday,friday

Page 11

Codian MCU 4200 Series Remote Management API 2.15 participant.fecc Parameter Type Comments conferenceName string autoAttendantUniqueId string p

Page 12

Codian MCU 4200 Series Remote Management API Contents Introduction ...

Page 13 - 2.8 participant.connect

Codian MCU 4200 Series Remote Management API Parameter Type Comments videoTxFrameRate int videoRxFrameRate int videoRxFramesReceived int v

Page 14 - 2.11 participant.enumerate

Codian MCU 4200 Series Remote Management API 3 Deprecated messages These messages are those that were supported in v1.0 of the MCU 4200 Series Ma

Page 15

Codian MCU 4200 Series Remote Management API Response Type Comments participantName string The participant name supplied in the conference.pa

Page 16 - 2.12 conference.enumerate

Codian MCU 4200 Series Remote Management API 4 Required user privileges The following table summarises which users are permitted to perform which

Page 17

Codian MCU 4200 Series Remote Management API 5 Fault Codes Fault Code Description 1 Method not supported 2 Duplicate conference name 3 Dupli

Page 18 - 2.14 autoAttendant.destroy

Codian MCU 4200 Series Remote Management API 6 Participant disconnect reasons These are the possible values of the “disconnectReason” field in pa

Page 19 - 2.15 participant.fecc

Codian MCU 4200 Series Remote Management API h245ProtocolError h245DecodeError q931DecodeError q931ProtocolError 7 References [1] XML-RPC,

Page 20

Codian MCU 4200 Series Remote Management API Appendix A - Conference Layouts The conference.participant.add and conference.participant.modify met

Page 21 - 3 Deprecated messages

Codian MCU 4200 Series Remote Management API The “<index>” values for “layout<index>” correspond to the pane arrangements shown below:

Page 22

Codian MCU 4200 Series Remote Management API 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59

Page 23 - 4 Required user privileges

Codian MCU 4200 Series Remote Management API Introduction The Codian MCU 4200 series products are controllable via messages sent using the XML-RPC

Page 24 - 5 Fault Codes

Appendix B - Linking conferences across MCUs For the purposes of this description, two conferences are said to be "linked" if there is a bi

Page 25

Codian MCU 4200 Series Remote Management API <member> <name>conferenceID</name> <value>

Page 26 - 7 References

Codian MCU 4200 Series Remote Management API <struct> <member> <name>authenticationUser</name&g

Page 27

Codian MCU 4200 Series Remote Management API <string>admin</string> </value> </member>

Page 28

Codian MCU 4200 Series Remote Management API <member> <name>authenticationUser</name> <value> <string>api_test</s

Page 29

Codian MCU 4200 Series Remote Management API </param> </params> </methodResponse> If the command fails, the MCU will send a fau

Page 30 - "mcu1"

Codian MCU 4200 Series Remote Management API 2 Messages Authentication All messages must contain a user name and password as follows: Parameter

Page 31 - "linked1"

Codian MCU 4200 Series Remote Management API Parameter Type Comments conferenceName string (<32 chars) Name of the conference to be created

Page 32

Codian MCU 4200 Series Remote Management API fourth last = last X of the month weekDays(optional) string Must be present if repetition is “weekl

Page 33 - B.5 Message responses

Codian MCU 4200 Series Remote Management API Parameter Type Comments conferenceName string (< 32 chars) Name of the conference to modify ne